BioCompatability of Metal Coated Spheres
For those scientists who are looking to use silver coated materials such as silver coated microspheres in biomedical applications, it is important to understand whether they are bio-compatable. A selection of abstracts and article references related to the biocompatability of silver follow:
The Biocompatibility of Silver2
The experiments reported have referred to some of the characteristics of the biocompatibility of Ag. Silver has been shown to display interactions with albumin, as an example of a plasma protein, quite different from those of most metals. Such studies shed further light on the complex issue of protein adsorption on biomaterials. It has also been demonstrated that Ag at concentrations < 1 ppm exerts a considerable influence on the activity of lactate dehydrogenase, this effect being reversed in the presence of albumin. A significant but transient increase in blood levels of Ag following intramuscular implantation of the metal has been observed. This is not reflected in any raised urine level. It is proposed that the richly vascular tissue immediately surrounding the implant in the acute phase of the response gives rise to the transient increase, but a subsequent decrease in vascularity reduces this possibility. It appears that Ag released from implants following this initial period substantially remains in the local area.2
Lack of toxicologocial side-effects in silver-coated megaprostheses in humans1
Deep infection of megaprostheses remains a serious complication in orthopedic tumor surgery. Furthermore, reinfection gets a raising problem in revision surgery of patients suffering from infections associated with primary endoprosthetic replacement of the knee and hip joint. These patients will need many revision surgeries and in some cases even an amputation is inevitable. Silver-coated medical devices proved their effectiveness on reducing infections, but toxic side-effects concerning some silver applications have been described as well. Our study reports about a silver-coated megaprosthesis for the first time and can exclude side-effects of silver-coated orthopedic implants in humans. The silver-levels in the blood did not exceed 56.4 parts per billion (ppb) and can be considered as non-toxic. Additionally we could exclude significant changes in liver and kidney functions measured by laboratory values. Histopathologic examination of the periprosthetic environment in two patients showed no signs of foreign body granulomas or chronic inflammation, despite distant effective silver concentrations up to 1626 ppb directly related to the prosthetic surface. In conclusion the silver-coated megaprosthesis allowed a release of silver without showing any local or systemic side-effects.1
Specific Article References for the biocompatability of silver are below: See the References
-
Metal Coated Microspheres – Conductive Silver Coating
From early days engineers have been looking for ways to shield circuits from electromagnetic interference (EMI). One of the most effective methods of shielding is by creating an electrically conductive enclosure around the circuit or device. This can be accomplished by using any electrically conductive material. Advances in coated microspheres have enabled the creation of light weight electrically conductive coatings that provide excellent EMI shielding.
Electrically conductive microspheres are produced by applying a metallic silver coating to the surface of the microspheres, thus giving the advantages of a metal particle with the additional properties of the core microsphere. Typically hollow glass microspheres are silver coated as this offers the combination of a low density filler and a conductive particle. Coatings with EMI shielding of greater than 45db have been produced by adding as little as 20% by weight of M-18 silver coated microspheres.Cospheric offers metal coated (silver) electrically conductive microspheres in a variety of sizes and densities as shown in the table below, custom particle size ranges are also available:
Product Average particle size (μm) Particle size range (μm) True particle density (g/cm3) Bulk density (g/cm3) Crush strength (psi) M-18 17 5–30 (std) 0.72 0.34 28000 M-30 27 10–45(std) 0.62 0.37 18000 M-40 36 15–70 (std) 0.49 0.35 6000 M-45 43 15–80 (std) 0.32 0.20 2000 M-60 74 25–120(std) 0.16 0.10 300